Appendix E: MSG_Exception Messages
186 FlashCONNECT Administrators Guide
FCisapi.dll: Redirect string too long, FCCBLocSize
FCServiceStore::D3SeverNew() s.consume
listen() failed
Protocol Version Mismatch, ProtocolVersion
Semaphore consumption failed, errorcode
Semaphore consumption failed, errorcode
Meaning: Buffer overrun in FCisapi (Windows) only.
Severity: Page will fail.
Action: Verify expected size of returned page.
Meaning: Unable to get a semaphore for a new worker thread.
Severity: Page will fail. FCService will not process pages.
Action: Verify that a process can have as many threads as are being started.
Meaning: listen returned a non-zero value for a w3socket.
Severity: FCService will fail.
Action: Contact Raining Data Customer Support.
Meaning: Internal protocol versions of FCService and the FlashCONNECT
database component (www account) do not match.
Severity: FCService will fail.
Action: Reload one version or the other to synchronize the versions.
Meaning: Failure attempting to consume the semaphore.
Severity: Page will fail.
Action: Check errorcode.
Meaning: WaitForSingleObject failed for semaphore.
Severity: FCService will fail.
Action: Check errorcode and resolve underlying problem.